Suzuki Ignis Service Manual page 3578

Rg413
Table of Contents

Advertisement

Starting Motor Dismounting and Remounting
Dismounting
1) Disconnect negative (–) battery lead at battery.
2) Disconnect magnetic switch lead wire (1) and battery cable (2) from starting motor terminals.
3) Remove starting motor mount bolt (3) and nut (4).
4) Remove starting motor (5).
Remounting
Reverse the dismounting procedure.
Tightening torque
Starting motor battery cable nut (a): 10 N·m (1.0 kg-m, 7.5 lb-ft)
Starting motor mount bolt and nut (b): 45 N·m (4.5 kg-m, 32.5 lb-ft)
No-load performance test
Connect battery and ammeter to starter as shown.
Check that starter rotates smoothly and steadily with pinion mov-
ing out. Check that ammeter indicates specified current.
Specified current (No-load performance test)
0.8 kW TYPE: 53 A MAX. at 11.5 V
1.2 kW TYPE: 90 A MAX. at 11 V
ON-Vehicle Service
CRANKING SYSTEM 6G-5