6B-14 ENGINE COOLING
2
3
1
4
Installation
Reverse removal procedure for installation noting the following.
• Refill cooling system referring to step 7) to 18) of "Cooling
System Flush and Refill" in this section.
• After installation, verify there is no coolant leakage at each
connection.
Radiator Cooling Fan Inspection
1) Check continuity between terminals. If there is no continuity,
replace radiator fan motor.
2) Connect battery to radiator fan motor coupler as shown in
figure, then check that the radiator fan motor operates
smoothly. If radiator fan motor does not operate smoothly,
replace motor.
Radiator cooling fan motor specified current at 12 V
10.0 A maximum
Water Pump/Generator Drive Belt Removal
and Installation
Removal
1) Disconnect negative cable at battery.
2) If vehicle equipped with A/C, remove compressor drive belt
(4) before removing water pump belt (1).
Refer to "Compressor Drive Belt Replacement" in Section
1B.
3) Loosen drive belt adjusting bolt (2) and generator pivot bolt
(3).
4) Slacken belt by displacing generator and then remove it.

Advertisement