8G-24 IMMOBILIZER CONTROL SYSTEM
Procedure After ECM Replacement
When ECM was replaced, including when replaced because rechecking by using a known-good ECM was nec-
essary during trouble diagnosis, register ECM/Immobilizer Control Module code in ECM by performing following
procedure.
1) Perform steps 1) and 2) described in "How to Register Ignition Key". And then turn ignition switch ON.
2) Using Suzuki Scan Tool, register ECM/Immobilizer Control Module code in ECM.
NOTE:
For operation procedure of Suzuki Scan Tool, refer to operator's manual for Suzuki Scan Tool.
3) Make sure that malfunction indicator lamp lights when ignition switch is turned OFF once and then ON.
Tech 2 kit (Suzuki Scan
Tool) See NOTE below.
NOTE:
This kit includes the following items.
1. Tech 2, 2. PCMCIA card, 3. DLC cable, 4. SAE16/19 adapter, 5. Cigarette cable,
6. DLC loopback adapter, 7. Battery power cable, 8. RS232 cable, 9. RS232 adapter,
10. RS232 loopback connector, 11. Storage case, 12. Power supply
Special Tool