Verifying Firmware Level of the Slave Modules
To ensure reliable multi-module operation, the slave modules must be at the same firmware level as the
Master module. The firmware of the slave modules can be flashed using the firmware image of the
Master.
Verify the firmware level of the slave modules as follows:
1) After the POST completes, press Menu on the first slave module.
2) Press Library Info in the View System Data area.
3) The firmware revision appears on the Miscellaneous Library Info screen.
4) Repeat steps (1) through (3) for the other Slave modules.
If any of the slave modules are at a different firmware level than the Master, flash the multi-module
system using the Master module GUI (if firmware Version 2.33 or higher is installed). WEB TLC or the
NeoCenter utility connected to the Master module may also be used to flash the modules.
NOTE: Refer to the Neo Series Installation and User Manual for instructions on using the
NeoCenter Utility or the WebTLC to upgrade the firmware. For additional assistance,
contact Overland Data Technical Support.
After the flash operation completes, the slave modules will reboot. After completion of the POST, the
system is ready for operation.