5 Repair
5.9.1 Replacing the axis-1 gearbox
Continued
3
4
5
Disconnecting the axis-1 motor cables
1
2
Continues on next page
458
Action
Hold the mechanical stop pin in a firm grip,
and remove it by unscrewing the set screw.
Foundry Plus
Remove the axis-1 cable protection plate by
removing the attachment screws.
Begin draining the axis-1 gearbox.
Note
There will be some oil left in the gear after
draining.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
Remove the motor cover by removing the
screws.
© Copyright 2023 ABB. All rights reserved.
Note
xx2200001398
xx2200001430
See
Floor-mounted robot: Draining the
axis-1 gearbox on page
Note
Product manual - IRB 6730
3HAC085699-001 Revision: B
138.