ABB IRB 6730 Product Manual page 268

Table of Contents

Advertisement

5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued
5
6
7
8
Continues on next page
268
Action
Remove the arm house cover screws.
Insert two screws M6 x minimum 70 mm on each
short side, as support so that the cover doesn't
fall down when pressed out.
Fit the M12 bolt and rotate it to press out the
complete cover.
Remove the complete cover.
Remove and save the oil plugs for refitting on the
new cover.
WARNING
Oil residues will drip out during removal.
Make sure that protective gear like goggles and
gloves are always worn.
WARNING
Handling gearbox oil involves several safety risks,
see
Gearbox lubricants (oil or grease) on page
WARNING
Used oil is hazardous material and must be dis-
posed of in a safe way. See
page 635
for more information.
© Copyright 2023 ABB. All rights reserved.
Note
xx2100001255
Screw, M6 x minimum 70 mm
xx2200001144
xx2100001256
xx2100001286
29.
Decommissioning on
Product manual - IRB 6730
3HAC085699-001 Revision: B

Advertisement

Table of Contents
loading

Table of Contents