5 Repair
5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Continued
3
4
5
Continues on next page
264
Action
DressPack
Loosen the insert.
(Cable guard (C) is available for protection
type Foundry Plus.)
DressPack
Push the DressPack tube a little back-
wards.
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
removal and to avoid damaging the parts.
This will also make it easier to run the cable
harness through the inside of the upper
arm.