ABB IRB 6730 Product Manual page 286

Table of Contents

Advertisement

5 Repair
5.6.1 Replacing the wrist
Continued
5
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
1
2
3
Continues on next page
286
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
If DressPack MH3 is installed:
Remove the wrist bracket with the complete
ball joint housing still fitted, if the bracket
is installed over the two wrist screws.
Note
No need to remove the bracket if the two
wrist screws are accessible.
If DressPack is installed:
Open the ball joint housing on the arm tube
and remove the DressPack cable package.
© Copyright 2023 ABB. All rights reserved.
Note
Note
xx2300001366
xx2100002709
Product manual - IRB 6730
3HAC085699-001 Revision: B

Advertisement