4 Maintenance
4.4.8 Replacing the SMB battery
Continued
2
3
4
5
6
Refitting the battery
Use this procedure to refit the SMB battery.
1
Continues on next page
168
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
is sensitive to ESD on page
Remove the SMB battery cover by unscrewing the
attachment screws.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
Pull out the battery and disconnect the battery
cable.
Remove the SMB battery.
Note
Battery includes protection circuits. Only replace
with a specified spare part or with an ABB-ap-
proved equivalent.