ABB IRB 6730 Product Manual page 566

Table of Contents

Advertisement

5 Repair
5.9.3 Replacing the axis-3 gearbox
Continued
Preparations prior to refitting motor
1
2
3
4
Refitting the axis-3 motor
1
Continues on next page
566
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove any old paint or flange sealant residues
or other contamination from the contact surfaces
on both the motor and the mating parts.
Tip
Remove flange sealant residues with Loctite 7200.
Then use Loctite 7063 for cleaning the mating
surface.
Apply a continuous bead of flange sealant, 1-2
mm wide, inside of the groove on the motor con-
tact surface.
Note
The purpose of the groove is to catch excess
sealant. No o-ring is used.
Remove the cover, if fitted to the new spare part
motor.
Action
Fit guide pins in opposite holes.
© Copyright 2023 ABB. All rights reserved.
Note
Cleaning agent: Loctite 7200, Loc-
tite 7063
Flange sealant: Loctite 5800
xx2100000520
Note
Guide pin, M10x150: 3HAC15521-2
Always use guide pins in pairs.
xx2100002151
Product manual - IRB 6730
3HAC085699-001 Revision: B

Advertisement

Table of Contents
loading

Table of Contents