ABB IRB 6730 Product Manual page 243

Table of Contents

Advertisement

Restoring the balancing device and removing the Hydraulic press equipment, balancing device
1
Concluding procedure
1
Product manual - IRB 6730
3HAC085699-001 Revision: B
5.4.2 Replacing spherical roller bearing, balancing device link ear
Action
Restore the balancing device and remove
the press equipment according to instruc-
tions for the press equipment.
xx0900000813
Go to the user instructions enclosed with
the press tool.
DANGER
Handling the tool incorrectly will cause
serious injury.
Read and follow enclosed user instructions
for the tool.
Apply flange sealant and refit the cover
plate on the back of the balancing device.
Action
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page
© Copyright 2023 ABB. All rights reserved.
Note
User instructions are enclosed with the
tool.
Hex socket head cap screw: M10x25 8.8-
A3F.
Tightening torque: 50 Nm.
Flange sealant for conical fittings: Loctite
5400 (or equivalent Loctite 577).
xx2200001330
Note
Test run after
96.
5 Repair
Continued
243