Removing the gearbox
Use these procedures to remove the axis-6 gearbox.
Preparations before removing the axis-6 gearbox
1
2
3
4
5
6
Product manual - IRB 6740
3HAC085701-001 Revision: A
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
Drain the gearbox.
Remove all equipment fitted on the turning
disc.
Jog the robot into position:
Axis 1 = no significance
Axis 2 = suitable working position to
replace axis-6 gearbox (for example:
+25°)
Axis 3 = suitable working position to
replace axis-6 gearbox (for example:
+20°)
Axis 4 = 0°
Axis 5 = -55°
Axis 6 = 0°
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
© Copyright 2023 ABB. All rights reserved.
5.9.4 Replacing the axis-6 gearbox
Note
See
Draining the axis-6 gearbox on
page
163.
Continues on next page
5 Repair
Continued
593