ABB OmniCore IRB 6740 Product Manual page 219

Table of Contents

Advertisement

3
4
5
6
Product manual - IRB 6740
3HAC085701-001 Revision: A
Action
Unscrew the attachment screws on each
shaft.
Remove the retaining ring on one side.
Push the balancing device against the side
where the retaining ring is removed, to
push in the shaft end and make the balan-
cing device go free.
If this is not possible, the shaft end must
be pulled out a bit with the dismantle and
mounting tool, see
Removing the shaft end,
cradle on page
249.
CAUTION
The weight of the balancing device (exclud-
ing cradle) is 140 kg
All lifting accessories used must be sized
accordingly.
© Copyright 2023 ABB. All rights reserved.
5.4.1 Replacing the balancing device
Note
xx2200001465
M16x70 quality steel 12.9 Gleitmo 603
xx2200001466
xx2200001467
Continues on next page
5 Repair
Continued
219