ABB OmniCore IRB 6740 Product Manual page 327

Table of Contents

Advertisement

Consumable
Locking liquid
Sealing compound
Required tools and equipment
Equipment
Standard toolkit
Refitting the cable harness - base, frame and lower arm
These procedures describes how to refit the cable harness in base, frame and
lower arm.
Preparations before refitting the cable harness
Use this procedure to understand the layout of the new cable harness spare part.
1
Refitting the cable harness in the lower arm
1
Product manual - IRB 6740
3HAC085701-001 Revision: A
Action
Floor-standing robot:
Lay the new cable harness on the floor, and place
the lower part around the manipulator to under-
stand the layout.
Action
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
procedure and to avoid damaging the parts
during the procedure.
This will also make it easier to run the cable
harness through the inside of the robot.
© Copyright 2023 ABB. All rights reserved.
5.7.2 Refitting the cable harness
Article number
Note
-
Loctite 2400 (or equivalent Loctite
243)
3HAC026759-002
Sikaflex 521 FC
Article number
Note
-
Content is defined in section
Standard toolkit on page
Note
Note
xx1300000668
5 Repair
Continued
652.
Continues on next page
327

Advertisement

Table of Contents
loading

Table of Contents