ABB OmniCore IRB 6740 Product Manual page 375

Table of Contents

Advertisement

7
8
9
Connecting the motor cables
1
2
Product manual - IRB 6740
3HAC085701-001 Revision: A
Action
Secure the motor with its attachment screws and
washers.
Use a bits extender to reach the screws.
Disconnect the brake release tool.
Perform a leak-down test.
Action
Put the motor cables in place in the open-
ing.
Refit the cable bracket with the screws.
© Copyright 2023 ABB. All rights reserved.
5.8.1 Replacing the axis-1 motor
Note
Hex socket head cap screw:
M10x30 12.9 Gleitmo 603+Geomet
500 (4 pcs)
Bits extender: 3HAC12342-1
Tightening torque: 50 Nm.
xx2200001794
See
Performing a leak-down test
on page
178.
Note
Torx pan head screw: M3x12 Stainless
steel A2-70
xx2200001738
Continues on next page
5 Repair
Continued
375

Advertisement

Table of Contents
loading

Table of Contents