5.5.1 Replacing the arm house cover including the axis-4 cassette sealing
Action
Use caution and push the cable harness
into the wrist.
Tip
This step is best performed by two persons
working together:
Person 1: Put one hand inside the
side cover hole and take a hold of
the cable harness.
Person 2: Take a hold of the cable
harness from inside the wrist.
Together: Move the cable harness
past the axis-5 motor and into the
wrist.
Refit the metal clamp axis-4, inside the arm
tube.
Note
The screw is reached from outside the up-
per arm.
© Copyright 2023 ABB. All rights reserved.
Note
Person 1, working at the side hole:
xx2300000035
Person 2, working at the wrist:
xx2300000041
Torx pan head screw: M6x16 A4-80
Tightening torque: 10 Nm.
xx2300000033
xx2300000032