5 Repair
5.6.1 Replacing the wrist
Continued
Removing the wrist
Use these procedures to remove the wrist.
Preparations before removing the wrist
1
2
3
4
Retrieving access to the wrist cabling
Use this procedure to remove the wrist cover.
1
Continues on next page
284
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
Remove tools and other equipment fitted
to the wrist.
Jog the robot into position:
Axis 1: no significance
Axis 2: jog axis 2 and 3 to a position
where the upper arm is horizontal
Axis 3: jog axis 2 and 3 to a position
where the upper arm is horizontal
Axis 4: +90°
Axis 5: +90°
Axis 6: no significance
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safe-
guarded space.
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
© Copyright 2023 ABB. All rights reserved.
Note
xx2100002164
Note
Product manual - IRB 6740
3HAC085701-001 Revision: A