5 Repair
5.7.4 Replacing the SMB unit
Continued
2
Concluding procedures
1
2
364
Action
Refit the electronic box with the attachment screws.
Action
Update the revolution counters.
DANGER
Make sure all safety requirements are met when
performing the first test run. See
installation, maintenance, or repair on page
© Copyright 2023 ABB. All rights reserved.
Note
Torx pan head screw: M6x60 (4
pcs)
Tightening torque: 10 Nm.
xx2200001721
Note
See
Updating revolution counters on
page
616.
Test run after
96.
Product manual - IRB 6740
3HAC085701-001 Revision: A