ABB OmniCore IRB 6740 Product Manual page 477

Table of Contents

Advertisement

Removing the cassette sealing
1
Refitting the axis-1 gearbox to the base
1
2
3
Product manual - IRB 6740
3HAC085701-001 Revision: A
Action
Remove the cassette sealing by knocking it down
through the frame.
Action
Lower the gearbox very carefully onto the
guide pins and onto the sealing tube.
Note
Check that the gearbox is oriented in the
same direction as the old gearbox, by
checking the orientation of the guiding pin.
Note
Make sure that the o-ring is still fitted cor-
rectly when the gearbox is being fitted.
Remove the guide pins.
Remove the lifting accessory and the lifting
eyes.
© Copyright 2023 ABB. All rights reserved.
5.9.1 Replacing the axis-1 gearbox
Note
xx2300000658
Note
xx2300000012
Continues on next page
5 Repair
Continued
477