6 Calibration
6.4.4 Axis Calibration - Running the calibration procedure
Continued
Calibration of the robot is not finished until the calibration data is saved, as last
step of the calibration procedure.
Preparation prior to calibration
The calibration procedure is described in the FlexPendant while conducting it.
1
2
3
Starting the calibration procedure
Use this procedure to start the Axis Calibration routine on the FlexPendant.
1
2
Continues on next page
296
6 Remove the protective cover from the fixed pin and the protection plug from
the bushing, if any, and install the calibration tool.
7 The robot performs a measurement sequence by rotating the axis back and
forth.
8 Remove the calibration tool and reinstall the protective cover on the fixed
pin and the protection plug in the bushing, if any.
9 The robot moves to verify that the calibration tool is removed.
10 Choose whether to save the calibration data or not.
Action
DANGER
While conducting the calibration, the robot needs
to be connected to power.
Make sure that the robot's working area is empty,
as the robot can make unpredictable movements.
Wipe the calibration tool clean.
Note
The calibration method is exact. Dust, dirt or color
flakes will affect the calibration value.
Check if the standard calibration data for axes 4
or 5 are updated with wrist optimization.
This is shown in the calibration overview/summary
window on the FlexPendant.
Action
Tap the calibration icon and enter the calibration
main page.
All mechanical units connected to the system are
shown with their calibration status.
Tap the mechanical unit in question.
Note
For RobotWare 7, the mechanical unit page is
displayed only if there is more than one mechan-
ical unit available.
© Copyright 2022 ABB. All rights reserved.
Note
Use a clean cloth.
If the data is optimized, the calibra-
tion routine Wrist Optimization
must be re-run after standard calib-
ration.
See
Calibrating with Wrist Optimiza-
tion method on page
302.
Note
Product manual - IRB 1010