Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
xx1500000951
A
Periodic check of the calibration tool with smaller outer diameter (3HAC058238-001)
If including the calibration tool with smaller outer diameter in a local periodic check
system, the following measures should be checked.
.
xx1600001142
A
Product manual - IRB 1010
3HAC081964-001 Revision: B
•
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
•
Straightness within 0.005 mm.
Outer diameter
•
Outer diameter within Ø5g5 mm.
•
Straightness within 0.005 mm.
Outer diameter
© Copyright 2022 ABB. All rights reserved.
6.4.2 Calibration tools for Axis Calibration
6 Calibration
Continued