Removing the process hub
1
2
3
4
Product manual - IRB 1010
3HAC081964-001 Revision: B
Action
Remove the covers.
Wrist covers (A)
Tilt cover (B)
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
Remove the screws and carefully open the cover.
CAUTION
There is cabling attached to the cover. The cover
cannot be removed completely until the connect-
ors are removed.
For robots with air hoses
Disconnect the air hoses.
For robots with CP/CS cabling
Disconnect the connector.
R2.C1
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
© Copyright 2022 ABB. All rights reserved.
5 Repair
5.4.4 Replacing the wrist unit
Continued
Note
xx2200000553
Note
xx2200000030
xx2200000031
xx2200000032
Continues on next page
229