5 Repair
5.3.1 Replacing the cable package
Continued
5
Refitting the axis-5 motor
1
2
3
Continues on next page
150
Action
Connect the power supply to axis-3 motor and
release the axis-3 brake to move the axis 3 to zero
position. Then, disconnect the power supply.
Note
The robot is not connected to the controller during
replacement, power must be supplied to the con-
nector R1.MP according to the section
power to connector R1.MP on page
Action
Arrange the cable package as follows:
•
Cablings out from the process hub
- air hoses
- CP/CS cabling (connector R2.C1)
- axis-5 motor cablings (connectors MP5
and FB5)
•
Cablings out from the right side of wrist
unit (facing the tool flange)
- axis-6 motor cablings (connectors MP6
and FB6)
- pressure relief pipe connector
Check that:
•
all assembly surfaces are clean and without
damages
•
the motor is clean and undamaged.
Reconnect the connectors.
•
FB5
Tip
See the number markings on the connectors for
help to find the corresponding connector.