In the following table you will find the minimum pulse widths which are required to
release the assigned function at the X4 plug.
Function
Open nozzle
Close nozzle
Print start
Print stop
Turn off printer
Mirrored horizontally
Gauger synchronization signal
The function allocations of the inputs 1 up to 3 happen by the
software of the JET2 neo in the menu Main menu
You will find a circuit diagram of the interface in the appendix of this
manual!

5.5.5 USB-Connection

By the USB-connection you can connect all common USB-devices as e.g. mouse,
keyboard or USB-stick very simply. All data can be exchanged comfortable and
simply by the USB-connection. Software updates, exchange of variable printing data
or memory expansions can be carried out simply with the USB-stick.
Plug assignment:
(1)
All 24V inputs marked by (1) are fused by a common self-resetting 700mA fuse.
(2)
When changing the Jobselect inputs, the change must have been made within the bounce
time, i.e. the new Jobselect no. is not detected as valid until the end of this time.
Release R1.07 en
Transport/Start up
Minimum pulse width
300ms
300ms
500ms
500ms
750ms
200ms
200ms
I/O settings
Inputs.
Pin connection:
Pin
Designation
1
+V (+5V)
2
Data -
Pin
Designation
3
Data +
4
GND
Group 5