Group 7

7.7.2 Monitoring functions (Control functions)

7.7.2.1 Printgo- and strokego monitoring

Monitoring functions are particularly necessary with high printing speeds.
Examples: A Print Go is triggered and is printed. The next Print Go is triggered.
However if the writing procedure has not yet been ended an error
notification will be made on the display:
„error!!, a printgo occured while a print, was in progress. Prints will be
lost. Check also PG-distance."
If the print speed is too high with the parameters set, stroke errors can
occur. The following error notification appears on the display:
„error!!, a strokego occured while a stroke, was in progress so
strokes will be lost."
The speed must be reduced or device parameters altered!
Figure 89
With the touch field<control functions>
(156) various monitoring functions (control
functions) can be activated. The "activation
level" <E31> is called up.
With the touch fields <print go control>
(157) and <stroke go control> (158) the
functions can be activated or deactivated.
At the same time the current status "OFF"
or "ON" is shown in the fields.