Special Functions And Tools; Constant Bleed - Leibinger JET3 up Operating Manual

Hide thumbs Also See for JET3 up:
Table of Contents

Advertisement

Page 172

7.4.4 Special functions and tools

Under the tab <Special Functions/Tools> the following functions are available:
 Pressureless
 Constant Bleed
 Deplete Ink
 Deplete Solvent
 Calc Delay Time

7.4.4.1 Constant bleed

The function constant bleeding is only activated or functional under
the following device conditions:
 Ink suction is turned on
 Nozzle is closed
 Head cover is removed
By pressing the button <Constant Bleed> (1) the constant bleeding is started.
During the process the message „Constant Bleed" (2) is displayed. The bleeding can
be canceled any time by pressing on the button <Stop> (3). During this process
the visco pump is activated for 3 sec. every minute to ensure a purging of the
pump.
With the button <Add Solv> (4) you can add only solvent. This function provides
specially filling operations to bleed e.g. the solvent tube or to set the viscosity of
the ink faster to a lower value.
By adding solvent the ink can be diluted too strong. Therefore this
function should only be carried out by qualified personnel.
Release R1.06
Job Editor
 Calc last PG Drops
 Mix only Ink
 Mix only Solvent
 Fill up Routine
 Ignore error messages and warnings
ATTENTION
ATTENTION
Group 8