Keithley DMM7510 Reference Manual page 210

7 1/2 digit graphical sampling multimeter
Hide thumbs Also See for DMM7510:
Table of Contents

Advertisement

Model DMM7510 7½ Digit Graphical Sampling Multimeter Reference Manual
Using the front panel to save or append buffer content to files:
1. Insert a USB flash drive into the USB port.
2. Press the MENU key.
3. Under Measure, select Reading Buffers. The MANAGE READING BUFFERS window is
displayed.
4. Select the reading buffer that you want to save. For example, select testData.
5. Select the Save To USB button. A keyboard is displayed.
6. Enter the name of the file in which to save the readings.
You only have to enter the name of the file you want to save. It is not necessary to enter the file
extension. All files are saved as .csv files.
7. Press OK on the keyboard.
8. Select Yes to confirm saving the file. When the MANAGE READING BUFFERS window is
displayed again, the file is saved.
9. Press the HOME key to return to the Home screen.
Using SCPI commands to save or append buffer content to files:
Before using any of these commands, insert a USB flash drive into the USB port.
To save readings and formatted timestamps from the default buffer to a file named myData.csv on
a USB flash drive, send the following command:
TRACe:SAVE "/usb1/myData.csv", "defbuffer1"
To save readings and formatted timestamps from a reading buffer named testData to a file named
myData.csv on a USB flash drive, send the following command:
TRACe:SAVE "/usb1/myData.csv", "testData"
DMM7510-901-01 Rev. B / May 2015
Figure 116: MANAGE READING BUFFERS window
Section 3: Functions and features
3-27

Advertisement

Table of Contents
loading

Table of Contents