4.6 Protection Modes
PROTECTION
Protection Modes
OVP Range
4.7 Metering
MEASUREMENTS
AC Voltage (Vrms)
Frequency (Hz)
Fundamental Range
AC Current (Arms)
Current Crest Factor
AC or DC Power (W)
Apparent Power (VA)
Power Factor
4.8 Other Measurements
Measurements
1
For currents > 1.0 Arms
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Range
Resolution
Accuracy
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
1
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
Over Current fold-back or trip
Power fold-back or trip
Apparent Power fold-back or trip
Over Voltage trip
Over Temperature
0 - 105% Vmax
SPECIFICATION
0 – 340 VLN / 0-600 VLL
0.01 V
± 0.1% F.S.
15 - 5000 Hz
0.01 Hz
± 0.1% Rdg
See Model Tables page 8 & 9
0.01 Arms
15-45Hz, ± 0.25% of F.S.
45-500 Hz, ±0.1% F.S.
20-5,000 Hz, ± 0.5% F.S.
1.00 - 10.00
0.01
± 2.0% F.S.
See Model Tables page 8 & 9
Front panel & Browser: 1 W, Interfaces: 0.1 W
± 0.75 % F.S.
See Model Tables page 8 & 9
Front panel & Browser: 1 VA, Interfaces: 0.1 VA
± 0.75 % F.S.
0.00 - 1.00
0.01
Page 42 of 463