Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]STEP:PHASe:FINal#:MINimum?
This command returns the minimum permissible set value of the final
STEP phase angle for selected phase #
<nr1>
STEP:PHAS:FIN1:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:PHASe:FINal#:MAXimum?
This command returns the maximum permissible set value of the
final STEP phase angle for selected phase #
<nr1>
STEP:PHAS:FIN1:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:PHASe:FINal#:DEF?
This command returns the default set value of the final STEP phase
angle for selected phase #
<nr1>
STEP:PHAS:FIN1:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:PHASe:DELTa# < nr2 >, <cr>
This command sets the delta STEP phase angle for selected phase #
number. Only phase 1 (B) and 2 (C) are allowed.
Phase No., < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr1>, <cr>
STEP:PHAS:DELT1 240.0
[SOURce:]STEP:PHASe:DELTa#?
<nr1>
STEP:PHAS:DELT1?
240.0000
[SOURce:]STEP:PHASe:DELTa#:MINimum?
This command returns the minimum permissible set value of the
delta STEP phase angle for selected phase #
<nr1>
STEP:PHAS:DELT1:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
LMX SERIES™ OPERATION MANUAL