8.10.4 Analog Input Commands

These commands control the use of analog input signals to drive the output of the LMX
power source. These functions are comparable to those of the legacy AMX Series power
sources.
[SOURce:]ANalog:PROGramming#
[:MODE] [ 0 | OFF | 1 | AMP | 2 | AM | 3 | ADD ]
[:MODE]?
[:AMP]
:AM
:HPF
8.10.4.1
Analog Input Mode Commands
Change between off, amplifier mode, AM or addition to internal waveform.
Available modes:
Value
0 | OFF
1 | AMP
2 | AM
3 | ADD
[SOURce:]ANalog:PROGramming#[:MODE] 0,1,2,3/OFF,AMP,AM,ADD
[SOURce:]ANalog:PROGramming#[:MODE]?
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Applies to AMP and ADD modes
:OFFset
:DEFault?
:MAXimum?
:MINimum?
:OFFset?
Applies to AM mode
:GAIN
:DEFault?
:MAXimum?
:MINimum?
:GAIN?
:STATe
:STATe?
:FREQuency
:DEFault?
:MAXimum?
:MINimum?
:FREQuency?
Mode
Input disabled
Amplifier Mode
Amplitude Modulation mode
Addition or Summing mode
LMX SERIES™ OPERATION MANUAL