Pacific Power Source LMX Series Operation Manual page 252

Programmable ac power source
Table of Contents

Advertisement

Command Syntax
Description
VOLT:INIT? = ON
VOLT:INIT? = OFF
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]VOLTage[:AC]:INITial
This command is equivalent to the "[SOURce:]INITial <n>" command
but applies only to the AC1, AC2 and AC3 parameters.
Set points of the unit at power on will be the last set after power off.
The set points affected by this command are:
- Voltage AC1
- Voltage AC2
- Voltage AC3
Set points of the unit at power on will have a default value of:
- Voltage AC1 = 0V
- Voltage AC2 = 0V
- Voltage AC3 = 0V
< 0 | OFF | 1 | ON >
<b>
VOLT:AC:INIT OFF
[SOURce:]VOLTage[:AC]:INITial?
<b>
VOLT:AC:INIT?
0
[SOURce:]VPEAK:MARGin
This command sets the over voltage protection trip level as an
absolute value. Thus, if the output voltage exceeds the programmed
voltage + the Vpeak Margin, the OVP protection will trip off the
output and generate an OVP fault.
For example., if 230Vrms is programmed in AC mode and the Vpeak
margin is set to 20, the OVP will trip at 230 * 2 + 20 =345Vpeak.
0.0 – 500.0
<nr2>
VPEAK:MARG 20.0
[SOURce:]VPEAK:MARGin?
<nr2>
VPEAK:MARG?
20.0000