PROGram[:SELected]:SST? [,<nr1>] [,<cr>]
This command returns the Steady State Table settings of the selected
program only. The transient table data is not returned.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:SST? 2, USB
-> steady state table program data
PROGram:EXECuted:SST? [,<nr1>] [,<cr>]
This command returns the Steady State Table settings of the
executing program only. The transient table data is not returned.
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:EXEC:SST?
-> steady state table program data
PROGram[:SELected]:TT? [,<nr1>] [,<cr>]
This command returns the Transient Table settings of the selected
program only. The steady state table data is not returned.
Option: STYLE [,<nr1]
0 = Human readable Style A (default if omitted)
1 = Human readable Style B
2 = Binary Data Format. Can be more useful to search for differences
between programs.
See PROGram:TT? Command for formats
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
<cr>
PROG:TT? 1
-> transient table program data