Changing Shuttle Programming Resolution; Table 6-3: Changing Programming Resolution - Pacific Power Source LMX Series Operation Manual

Programmable ac power source
Table of Contents

Advertisement

USER PRESETS Screen" on page 145.

6.4.14 Changing Shuttle Programming Resolution

Once entering EDIT mode on any programmable field – by double clicking the shuttle knob –
the parameter value can be slewed by turning the knob. The setting resolution can be
changed as needed. If a large value change is needed, a lower resolution will result in a
faster change, e.g. changing voltage 10V per click or 1V per click. For a very small change, a
0.1V or 0.01V change per click may be more appropriate.
The selected resolution is reflected by the blinking character when in edit slew mode. To
change the position and thus resolution, use the keypad numeric keys. The lowest number
keys will select the smallest increment/decrement setting. The higher number keys will
select a larger increment/decrement setting.
The table bellows maps the keypad keys to the resolution setting.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Key Pad Key #
Position
1 or 2
3
4
5
6, 7, 8 or 9
7, 8, 9

Table 6-3: Changing Programming Resolution

LMX SERIES™ OPERATION MANUAL
Front Panel Operation
SECTION 6:
Resolution
0.01
0.1
1
10
100
1000
Page 106 of 463