Pacific Power Source LMX Series Operation Manual page 340

Programmable ac power source
Table of Contents

Advertisement

Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Query Format
Description
Parameters
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
SYSTem:AIO:INput[n]:OFFSET:DEFault?
Returns the default offset for the specified analog input.
None
n/a
SYST:AIO:IN1:OFFSET:DEF?
15.0
SYSTem:AIO:INput[n]:OFFSET:MAXimum?
Returns the maximum offset for the specified analog input.
None
n/a
SYST:AIO:IN1:OFFSET:MAX?
100000.000000
SYSTem:AIO:INput[n]:OFFSET:MINimum?
Returns the minimum offset for the specified analog input.
None
n/a
SYST:AIO:IN1:OFFSET:MIN?
-100000.000000
SYSTem:AIO:INput[n]:RANGe <nr2>
Sets the range of the specified analog input.
Available range is 0.0 ~ 10.
Offset
<nr2>
SYST:AIO:IN1:RANG 50.0
SYSTem:AIO:INput[n]:RANGe?
<nr2>
SYST:AIO:IN1:RANG?
10.00
SYSTem:AIO:INput[n]:RANGe:DEFault?
Returns the default range for the specified analog input.
None
n/a
SYST:AIO:IN1:RANG:DEF?
0.0
SYSTem:AIO:INput[n]:RANGe:MAXimum?
Returns the maximum range for the specified analog input.
None
n/a
SYST:AIO:IN1:RANG:MAX?
10.0