Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
8.7.5
Phase Programming Commands
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]IPEAK:PROTect:STATe
This command enables or disables the user programmable current
protection mode.
[ 0 | OFF | 1 | ON ]
<b>
IPEAK:PROT:STAT 1
[SOURce:]IPEAK:PROTect:STATe?
<nr1>
IPEAK:PROT:STAT?
1
[SOURce:]IPEAK:PROTect:LEVel
This command sets user programmable the peak current protection
mode level.
0.0000 – 100000.0000
<nr2>
IPEAK:LIM 50.0
[SOURce:]IPEAK:PROTect:LEVel?
<nr2>
IPEAK:PROT:LEV?
50.000
[SOURce:]PHASe#
This command programs the phase angle for the selected phase. A
phase reference (#) must be specified.
Note that unless external sync mode is used, the A phase (# = 1)
cannot be programmed is fixed at 0 degrees.
0.0 – 359.9
<nr2>
PHAS2 122.5
[SOURce:]PHASe#?
<nr2>
PHAS2?
122.5
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 258 of 463