[SOURce:]IPEAK:PROTect:STATe
This command enables or disables the user programmable current
protection mode.
[ 0 | OFF | 1 | ON ]
<b>
IPEAK:PROT:STAT 1
[SOURce:]IPEAK:PROTect:STATe?
<nr1>
IPEAK:PROT:STAT?
1
[SOURce:]IPEAK:PROTect:LEVel
This command sets user programmable the peak current protection
mode level.
0.0000 – 100000.0000
<nr2>
IPEAK:LIM 50.0
[SOURce:]IPEAK:PROTect:LEVel?
<nr2>
IPEAK:PROT:LEV?
50.000
[SOURce:]PHASe#
This command programs the phase angle for the selected phase. A
phase reference (#) must be specified.
Note that unless external sync mode is used, the A phase (# = 1)
cannot be programmed is fixed at 0 degrees.
0.0 – 359.9
<nr2>
PHAS2 122.5
[SOURce:]PHASe#?
<nr2>
PHAS2?
122.5