8.7.10 Impedance Programming Commands

These commands control the output impedance of the power source. The programmable
output impedance is defined by a resistive component ( R ) and and inductive component ( L
).
Note: To enable the programmable impedance function, the output of the power source
must be turned OFF first. Trying to enable this function while the output is ON will
result in an error message.
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Parameters
Parameter Format
Query Example
Query Syntax
Description
Parameters
Parameter Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]IMPEDance[:R]
This command sets the R value for the output impedance. Available
programming range depends on the mode (Real-time or RMS).
<R>
<nr2>
IMPED 0.2
[SOURce:]IMPEDance[:R]?
<nr2>
IMPED:R?
0.200
[SOURce:]IMPEDance[:R][:LIMit]:MAXimum?
This command return the maximum allowable setting value for the R
component of the output impedance.
None
N/A
IMPED:R:MAX?
1.000
[SOURce:]IMPEDance[:R][:LIMit]:MINimum?
This command return the minimum allowable setting value for the R
component of the output impedance.
None
N/A
IMPED:R:MIN?
-1.000
[SOURce:]IMPEDance:L
This command sets the L value for the output impedance. Available
programming range is
-0.00000000
<L>
<nr2>
IMPED:L 0.00002
[SOURce:]IMPEDance:L?
<nr2>
IMPED:L?
0.00002
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
~
0.00005000
(Henry).