Error Source
Code
Front panel
189
Front panel
190
Front panel
191
Front panel
192
Front panel
193
Front panel
329
Front panel
330
Front panel
331
Front panel
332
Front panel
333
Front panel
334
Front panel
335
Front panel
336
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
Error
Incompatible node
detected.
Error
Master unit nodes not
found.
Error
Fast scan failed.
Error
Undetectable node exists.
Error
An invalid firmware type
exists.
Internal
Global fault detected.
Error
Internal
Global fault detected.
Error
Possible un-energized
unit or node.
Error
Unit discovery fault. Run
unit discovery to recover.
Error
Undiscovered unit/node
detected. Run unit
discovery to recover.
Error
Node in non-operational
mode. Run unit discovery
to recover.
Error
Power failure.
Error
Remote inhibit was issued
from remote interface.
Error
System about to reboot.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
Error during discovery.
Error with one or more
Auxiliary units found
during discovery
Error during discovery.
One or more nodes in
Master unit not found
Error during discovery.
Fast scan discovery failed
An inconsistency was
detected in the power
source's internal
communication network.
Firmware Error. One or
more nodes report invalid
firmware type
An inconsistency was
detected in the power
source's internal
communication network.
Error during discovery.
Discovery of parallel units
failed
An inconsistency was
detected in the power
source's internal
communication network.
An inconsistency was
detected in the power
source's internal
communication network.
Setting conflict. Remote
inhibit conflicts with
Output state
Notification. Reboot
imminent. Normal after
Resolution
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Turn unit off, check
parallel cables if they
exist, and then turn unit
on. If problem recurs
contact customer service.
Check for correct
firmware image file and
version.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Check all parallel cables
between units. Run
parallel unit discovery
from System menu to
recover
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Turn unit off, check
parallel cable connections
if present and then turn
unit back on. If problem
recurs, contact customer
service.
Check AC input voltage. If
error persists, contact
customer service
Check Remote inhibit
mode setting and
connections
Wait for all firmware
updates to be completed
Page 446 of 463