7.12.7 External Sync
External sync is used to synchronize the power source's phase A output to an external
frequency.
Available settings are:
•
STATUS
•
EXTERNAL SYNC
SYNC SOURCE
•
•
Available sync sources are:
- External sync input on I/O connector
- LINE (AC input to power source)
PHASE SHIFT
•
•
SPEED
•
RANGE
•
EXTERNAL SYNC
7.12.8 Trigger Input
The External Trigger Input can be used to synchronize the power source's transient
execution to external equipment. This
Available settings are:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
SECTION 7: Auxiliary I/OError! Reference source not found.
Display SYNC Status
[ ON | OFF ]
Select Sync source
Offset Phase A angle
1.00 to 10.00
0.10 to 5000 Hz
[ ON | OFF ]