Sync Status Display; Sync Operation Settings - Pacific Power Source LMX Series Operation Manual

Programmable ac power source
Table of Contents

Advertisement

7.5.2

SYNC Status Display

A "Synced" status field will be displayed in
This field will toggle with the regular "Ready/Enabled/Fault" status field also shown in this
location. The "Synced" status will be shown every 3 seconds for 1 second in place of the
"Ready/Enabled/Fault" field. When the PLL is not locked to the external source, the unit will
display an "Unsynced" status in Orange.
It is not recommended to enable the unit when it has not locked or synchronized to the
external source because the frequency may be unknown.
7.5.3

Sync Operation Settings

The LMX allows precise configuration of the synchronization parameters to optimize
performance for each application. The parameters are:
1
Phase shift: Defines a fixed phase shift between phase A waveform generation and
the external sync source. Used to calibrate any phase difference between the sync
signal and the power source output on phase A.
Command: SOURce:SYNChronize:PHASEshift
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
SECTION 7: Auxiliary I/OError! Reference source not found.
Figure 7-4: External Sync Input Sync Status Indication
Figure 7-5: External Sync Input Sync Lost Status Indication
LMX SERIES™ OPERATION MANUAL
Green
in the lower left corner of the LCD display.
Page 184 of 463