10.8.5.2
Scope – Advanced
The ADVANCED scope function operates much the same as a digital storage oscilloscope having
controls for time base, attenuators and trigger mode settings. The amount of data points that
can be captured and stored ranges from 100 Samples to 1,000,000 samples (1Ms).
The advanced scope function has two channel, labeled CHANNEL A and CHANNEL B. Each
channel can be assigned to capture either voltage or current on any of the available output
phases. Vertical scaling can be set as well as DC offset for each channel as needed.