8.7.3

Frequency Programming Commands

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]FREQuency
Sets output frequency for all phases.
15.00 – 5000.0
Range is adjust on models with T Option
<nr2>
FREQ 400.0
[SOURce:]FREQuency?
<nr2>
FREQ?
400.0000
[SOURce:]FREQuency:LIMit:MINimum
Sets the lower user limit for frequency programming. Not that the
lower limit set value must be less than the upper limit set value or an
error will be generated and no change to the set value will take place.
The lower limit set value must fall within the source specified
frequency range capability.
15.00 – 5000.0
Range is adjust on models with T Option
<nr2>
FREQ:LIM:MIN 47.0
[SOURce:]FREQuency:LIMit:MINimum?
<nr2>
FREQ:LIM:MIN?
47.0000
[SOURce:]FREQuency:LIMit:MAXimum
Sets the upper user limit for frequency programming. Note that the
upper limit set value must be greater than the lower limit set value or
an error will be generated and no change to the set value will take
place. The upper limit set value must fall within the source specified
frequency range capability.
15.00 – 5000.0
Range is adjust on models with T Option
<nr2>
FREQ:LIM:MAX 63.0
[SOURce:]FREQuency:LIMit:MAXimum?
<nr2>
FREQ:LIM:MAX?
63.0000
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 254 of 463