Pacific Power Source LMX Series Operation Manual page 439

Programmable ac power source
Table of Contents

Advertisement

Error Source
Code
Front panel
-256
Front panel
-253
Front panel
-240
Front panel
-224
Front panel
-222
Front panel
-221
Front panel
-203
Front panel
-158
Front panel
-138
Front panel
-131
Front panel
-113
Front panel
-109
Front panel
-108
Front panel
-103
Front panel
-102
Front panel
18
Front panel
19
Front panel
21
Front panel
22
Front panel
29
Front panel
31
Front panel
32
Front panel
33
Front panel
34
Front panel
35
Front panel
36
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
SCPI error
Execution error: File not
found.
SCPI error
Execution error: Media is
corrupted.
SCPI error
Execution error:
Hardware error.
SCPI error
Execution error: Illegal
parameter value.
SCPI error
Execution error:
Argument out of range.
SCPI error
Execution error: Conflict
in configuration setting.
SCPI error
Execution error:
Permission denied.
SCPI error
Command error: String
data is not allowed.
SCPI error
Command error: Numeric
suffix is invalid.
SCPI error
Command error: Numeric
suffix is out of range.
SCPI error
Command error:
Undefined header.
SCPI error
Command error: Invalid
number of parameters.
SCPI error
Command error:
Parameters error.
SCPI error
Command error: Invalid
separator.
SCPI error
Command error: Syntax
error.
Error
Unavailable transient
element.
Error
Maximum number of
transient elements.
Error
Internal communication:
error during SDO upload.
Error
Internal communication:
error during SDO
download.
Error
USB interface unknown
state.
Error
Interface request packet.
Error
Interface request packet.
Error
Interface request packet.
Error
Interface request packet
out of space.
Error
Interface request packet.
Error
Interface request packet
has invalid arguments.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
File specified does not
exist
Media used has been
corrupted
Unspecified Hardware
Error detected. Cause
unknown
Invalid parameter value
Argument passed exceeds
allowable range
Configuration setting
conflict
Read or Write access to
memory selected denied.
Some memory areas are
off limits
Passing string data when
string type is not
supported
Number suffix not valid
Suffix number passed
exceeds allowable range
Command Header not
defined
Invalid number of
parameters. Too few or
too many parameters are
being passed
Errors in parameters
Separator used is invalid
Syntax Error
Resolution
Check for correct file
name
Reformat or replace
media
Try recycling power. If
error persists, contact
customer service
Check value
Adjust parameter to be
within valid range
Check configuration
settings
Check memory type or
permissions
Pass correct data type
Check value
Adjust suffix to be within
valid range
Check command
Check for correct no. of
parameters
Check parameter values
Use correct separator
character
Check syntax
Page 439 of 463

Advertisement

Table of Contents
loading

Table of Contents