Pacific Power Source LMX Series Operation Manual page 295

Programmable ac power source
Table of Contents

Advertisement

Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]STEP:PHASe:DELTa#:MAXimum?
This command returns the maximum permissible set value of the
delta STEP phase angle for selected phase #
<nr1>
STEP:PHAS:DELT1:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:PHASe:DELTa#:DEF?
This command returns the default set value of the delta STEP phase
angle for selected phase #
<nr1>
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP <cr>
>>> Alias for PROGram:TRANsient command. <<<
This command controls step transient execution
< RUN | STOP | PAUSe | STEP | RESTart >
<cr>
STEP RUN
[SOURce:]STEP?
Query format returns the step transient execution state as either
RUN, STOP, PAUS, STEP or REST
<nr1>
Return values respresent running state as follows:
0
Stopped
1
Running
2
Paused
3
Stepping
4
Waiting for trigger
STEP?
1