8.10.4.2
Analog Input Gain & Offset Commands
Change gain for amplifier and addition modes (default=250*xfmr-ratio)
[SOURce:]ANalog:PROGramming#[:AMP]:GAIN
[SOURce:]ANalog:PROGramming#[:AMP]:GAIN?
[SOURce:]ANalog:PROGramming#[:AMP]:GAIN:DEFault?
[SOURce:]ANalog:PROGramming#[:AMP]:GAIN:MAXimum?
[SOURce:]ANalog:PROGramming#[:AMP]:GAIN:MINimum?
Change offset of input signal (default = 0.0), useful for unipolar input signals:
[SOURce:]ANalog:PROGramming#[:AMP]:OFFset
[SOURce:]ANalog:PROGramming#[:AMP]:OFFset?
[SOURce:]ANalog:PROGramming#[:AMP]:OFFset:DEFault?
[SOURce:]ANalog:PROGramming#[:AMP]:OFFset:MAXimum?
[SOURce:]ANalog:PROGramming#[:AMP]:OFFset:MINimum?
Change gain for AM (=1.0 or 100% by default)
[SOURce:]ANalog:PROGramming#:AM:GAIN
[SOURce:]ANalog:PROGramming#:AM:GAIN?
[SOURce:]ANalog:PROGramming#:AM:GAIN:DEFault?
[SOURce:]ANalog:PROGramming#:AM:GAIN:MAXimum?
[SOURce:]ANalog:PROGramming#:AM:GAIN:MINimum?
Change offset for AM (default = 0)
[SOURce:]ANalog:PROGramming#:AM:OFFset
[SOURce:]ANalog:PROGramming#:AM:OFFset?
[SOURce:]ANalog:PROGramming#:AM:OFFset:DEFault?
[SOURce:]ANalog:PROGramming#:AM:OFFset:MAXimum?
[SOURce:]ANalog:PROGramming#:AM:OFFset:MINimum?
8.10.4.3
High Pass Filter Commands
Enable/Disable high pass filter at the analog programming, to block the DC (this may not be
very relevant for AC coupled sources, but it has an effect in AM), disabled by default.
[SOURce:]ANalog:PROGramming#:HPF:STATe
[SOURce:]ANalog:PROGramming#:HPF:STATe?
Change frequency of HPF (10Hz by default)
[SOURce:]ANalog:PROGramming#:HPF:FREQuency
[SOURce:]ANalog:PROGramming#:HPF:FREQuency?
[SOURce:]ANalog:PROGramming#:HPF:FREQuency:DEFault?
[SOURce:]ANalog:PROGramming#:HPF:FREQuency:MAXimum?
[SOURce:]ANalog:PROGramming#:HPF:FREQuency:MINimum?
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
[ 0 | OFF | 1 | ON ]
Page 356 of 463

Advertisement

Table of Contents
loading

Table of Contents