MEASure:SPECTrum:OHD?
Returns Odd Harmonic Distortion of the most recent
:MEASure:SPECTrum:parameter command
<nr2>
MEAS:SPECT:OHD?
3.5690
MEASure:SPECTrum:VOLTage#:OHD?
Same as "MEAS:SPECTrum:OHD?" but selects voltage and phase
#.Returns Odd Harmonic Distortion of the selected phase voltage.
<nr2>
MEAS:SPECT:VOLT1:OHD?
10.5891
MEASure:SPECTrum:VLL#:OHD?
Same as "MEAS:SPECTrum:OHD?" but selects Line to Line voltage
#.Returns Odd Harmonic Distortion of the selected Line to Line
voltage.
<nr2>
MEAS:SPECT:VOLT1:OHD?
10.5891
MEASure:SPECTrum:CURRent#:OHD?
Same as "MEAS:SPECTrum:OHD?" but selects current and phase
#.Returns Odd Harmonic Distortion of the selected phase currebt.
<nr2>
MEAS:SPECT:CURR1:OHD?
22.5948