7.3 Dedicated Function Digital Inputs
Remote Inhibit
•
External Trigger Input
•
External Phase Sync Input
•
7.3.1
Remote Inhibit
The mode can be selected from the SYST (SYSTEM) menu screen using the Interfaces,
Remote Inhibit selection as shown below.
There are three modes of operation for this input:
1. Disable mode: In his mode, the Remote Inhibit inputs are not active so this function
is turned off. No short between the RI pins is required to enable the output in this
mode.
2. Remote Inhibit mode: The two pins have to be shorted for the output to be enabled
from the front panel or remote command. This is a necessary but not a sufficient
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
LMX SERIES™ OPERATION MANUAL
SECTION 7: Auxiliary I/OError! Reference source not found.
REMOTE
INHIBIT
Page 180 of 463