Pacific Power Source LMX Series Operation Manual page 444

Programmable ac power source
Table of Contents

Advertisement

Error Source
Code
Front panel
154
Front panel
155
Front panel
156
Front panel
157
Front panel
158
Front panel
159
Front panel
160
Front panel
161
Front panel
162
Front panel
163
Front panel
166
Front panel
169
Front panel
172
Front panel
173
Front panel
174
Front panel
175
Front panel
176
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
Error
Steady state not yet
stabilized.
Error
Trigger output not
available in this model.
Error
Trigger input not
available in this model.
Error
Filter size must be an odd
number.
Error
Voltage mode not
available in UPC
compatible mode.
Error
Waveform is unique in
UPC compatible mode.
Error
Phase is 180 for split in
UPC compatible mode.
Error
Voltage AC is unique in
UPC compatible mode.
Error
CSC is always disabled
during transient in UPC
compatible mode.
Error
Auto RMS is always
enabled in UPC
compatible mode.
Error
Unable to set extended
voltage because
frequency is outside the
allowed range.
Error
Unable to update set
point because it is outside
the allowed range of
extended voltage mode
Error
Command not allowed
during power stage
firmware update.
Error
Cannot change Current
RMS Overload mode with
output enable.
Error
Strobe feature not
available in this model.
Error
Feature not available in
this model.
Error
Set points cannot be
changed while transient
program is running.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
??
Trigger Output not
supported. Feature not
available
Trigger Input not
supported. Feature not
available
Invalid Filter Number.
Filter size must be odd
number
Setting conflict. UPC
mode only supports AC
Mode
Setting conflict.
Requested waveform
supported in UPC mode
only
Setting conflict. Phase
angle 180 reserved for
Split phase mode in UPC
Mode
Setting conflict. UPC
mode only supports AC
Mode
Setting conflict. CSC
mode cannot be enabled
during transients
Setting conflict. Auto RMS
mode cannot be disable
in UPC mode
Setting conflict. Extended
AC voltage mode
available over limited
frequency range
Notification. Extended AC
voltage range derating
implemented
Notification. Firmware
update for Power Stage in
progress. Command not
allowed during this time.
Setting conflict. Current
RMS overload mode can
only be enabled with
output OFF
Function Strobe Output
not supported. Feature
not available
Feature not available.
Setting conflict.
Attempting to change
setting while transient
execution is in progress
Resolution
??
Requires AUX I/O board
Requires AUX I/O board
Change filter parameter
to even number
Change to LMX Mode
Change to UPC Mode
Change to LMX Mode
Change to LMX Mode
Change to LMX Mode
Change to LMX Mode
Adjust frequency to
within available range
Wait for all firmware
updates to be completed
Turn output OFF, then
enable Current RMS
Overload mode
Requires AUX I/O board
Requires AUX I/O board
Abort Transient Run or
wait for transient
execution to complete
Page 444 of 463