Pacific Power Source LMX Series Operation Manual page 275

Programmable ac power source
Table of Contents

Advertisement

Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]PROTect[:RMS]:POWer:TDELAY:DEFault?
This command returns the default true power protection trip delay
time setting.
PROT:POW:TDELAY:DEF?
5
[SOURce:]PROTect[:RMS]:POWer:TRIPped?
This command returns the true power protection trip status. Returns
1 if tripped or 0 if not.
PROT:POW:TRIP?
41.667
[SOURce:]PROTect[:RMS]:POWer:TRIPped:CLEar
This command clears the true power protection trip status. Once
cleared, the power source output can be enabled.
None
n/a
PROT:POW:TRIP:CLE
[SOURce:]PROTect[:RMS]:KVA[:STATe] <ON|OFF>
This command turns the apparent power protection on or off.
< 0 | OFF | 1 | ON >
<b> | <cr>
PROT:POW ON
[SOURce:]PROTect[:RMS]:KVA[:STATe]?
<b>
PROT:KVA?
1
[SOURce:]PROTect[:RMS]:KVA:LEVel <LEVEL>
This command sets the apparent power protection trip level. Setting
is in KW.
< LEVEL >
<nr2>
PROT:POW:LEV 5
[SOURce:]PROTect[:RMS]:KVA:LEVel?
<b>
PROT:KVA:LEV?
5.000
[SOURce:]PROTect[:RMS]:KVA:LEVel:MINimum?
This command returns the minimum apparent power protection level
setting.
PROT:KVA:LEV:MIN?
0.000
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 275 of 463

Advertisement

Table of Contents
loading

Table of Contents