Error Source
Code
Front panel
75
Front panel
76
Front panel
77
Front panel
78
Front panel
79
Front panel
80
Front panel
83
Front panel
84
Front panel
85
Front panel
89
Front panel
90
Front panel
91
Front panel
95
Front panel
96
Front panel
97
Front panel
98
Front panel
99
Front panel
100
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
Error
IP address conflict. May
be duplicated.
Error
Invalid filename.
Error
External memory storage
is not available.
Error
Data logger rate not
allowed.
Event
Data logger is running
Error
Data logger execution
error.
Event
Internal error: File system
partition blocked.
Event
Unable to change form
while output is enabled.
Error
Unable to clear one or
more fault.
Error
Digital I/O interface
conflict: Remote inhibit is
active.
Error
Digital I/O interface
conflict: Remote enable is
active.
Error
Internal error: Unknown
phase mode.
Error
Digital I/Os interface
conflict: Serial interface
flow control is active.
Error
Data logger storage error.
Error
Output enable in
progress.
Error
DC Voltage not allowed in
"AC mode".
Error
AC Voltage not allowed in
"DC mode".
Error
DC voltage set point
cannot change due to
user limit.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
Duplicate IP detected
File name invalid
Can't find external
memory device selected.
External storage device
selected may have been
removed
Data logging rate set is
invalid
Trying to change
configuration settings
while data logging is in
progress. Stop data
logger function before
changing configuration
Error during data logging
Trying to change phase
mode while output is ON.
Phase mode (FORM)
cannot be changed while
output is ON
Could not clear one or
more faults when
requested
Conflict between front
panel and Remote Inhibit
input level
Conflict between front
panel and Remote
Enable input level
Selected Phase Mode
(FORM) is unknown
RS232 or USB interface
error
Error saving
measurement data to
selecting memory device.
Memory device may have
been removed
Waiting to turn output
off. Changing from
Output ON to Output OFF
state
Setting conflict. Setting
does not match mode
Setting conflict. Setting
does not match mode
Setting conflict. Setting
outside of User Limits
Resolution
Check IP or renew lease
Check file name
Re-insert external
memory device or select
different memory type
Adjust logging rate
setting
Stop data logger function
before changing
configuration
Stop data logger function
Turn output OFF first,
then change FORM
Try recycling power. If
error persists, contact
customer service
Resolve conflict. Check
input to Remote Inhibit
Resolve conflict. Check
input to Remote Enable
Try recycling power. If
error persists, contact
customer service
Check RS232 or USB
settings
Check for Memory device
presence
Wait for power stages
and inverters to fully
engage
Check setting
Check setting
Check setting