[SOURce:]PULSe:WIDTh:MAXimum?
This command the returns maximum permissible set value for the
PULSE width.
<nr2>
PULS:WIDT:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]PULSe:WIDTh:DEFault?
This command returns the default set value for the PULSE width.
<nr2>
PULS:WIDT:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]PULSe:MODE <nr2>, <opt>
This command sets the pulse width in seconds.
< 0 | PW | 1 | PD | 2 | WD >
Encoding:
0 | PW program pulse by period and width
1 | PD
program pulse by period and duty cycle
2 | WD program pulse by width and duty cycle
<nr1> or <cr>
PULS:MODE WD
[SOURce:]PULSe:MODE?
<nr1>
PULS:MODE?
2
[SOURce:]PULSe:MODE:CATalog?
This command returns the available programming modes: "0,Period
and width,1,Period and duty cycle,2,Width and duty cycle".
None
<cr>
PULS:MODE:CAT?
0,Period and width,1,Period and duty cycle,2,Width and duty cycle
[SOURce:]PULSe:RAMP <nr2>, <opt>
This command sets the pulse ramp time in seconds.
Ramp time, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr2>, <cr>
PULS:RAMP 0.2
[SOURce:]PULSe:RAMP?
<nr2>
PULS:RAMP?
0.2